Dane techniczne

Ciecze
Zasada pomiaruCoriolis
Product headlineThe compact sensor with an ultra-compact transmitter. Measurement of liquids with the most diverse properties in continuous process control & batching applications.
Sensor featuresHigh process safety – high measuring accuracy for different media in shortest filling time. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Nominal diameter: DN 8 to 25 (³⁄₈ to 1"). Various hygienic process connections, 3-A conform. CIP, SIP cleanable sensor.
Transmitter featuresVersatile and time-saving wiring – plug connector. Fast commissioning – pre-configured devices. Automatic recovery of data for servicing. Robust, ultra‐compact transmitter housing. Pulse/frequency/switch output, Modbus RS485. Excellent and easily cleanable transmitter.
Średnica nominalna DN 8 to 25 (³⁄₈ to 1")
Materiały w kontakcie z medium Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)
Wielkości mierzone Mass flow, density, temperature, volume flow
Maksymalny błąd pomiaru Mass flow (liquid): ±0.15 %
Density (liquid): ±0.0005 g/cm³
Zakres pomiarowy 0 to 18 000 kg/h (0 to 660 lb/min)
Maks. ciśnienie procesu PN 40
Zakres temperatury medium –40 to +125 °C (–40 to +257 °F)
150 °C allowed for 1 h
Temperatura otoczenia –20 to +60 °C (–4 to +140 °F)
Materiał obudowy czujnika 1.4301 (304), corrosion resistant
Materiał obudowy przetwornika 1.4308 (304)
Stopień ochrony IP67, type 4X enclosure
Wyświetlacz No local operation
Configuration via operating tools possible
Wyjścia Pulse/frequency/switch output (passive)
Wejścia None
Komunikacja cyfrowa Modbus RS485
Zasilacz DC 20 to 30 V
Dopuszczenia do stosowania w strefach zagrożonych wybuchem ATEX, IECEx, cCSAus
Inne certyfikaty i dopuszczenia 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
3-A
Product safety CE