The refueling and distribution application flowmeter with easy sytem
integration. Accurate measurement of liquefied petroleum gas in refueling
and distribution applications.
The refueling and distribution application flowmeter with easy sytem integration. Accurate measurement of liquefied petroleum gas in refueling and distribution applications.
Sensor features
Excellent operational safety – reliable under extreme ambient conditions.
Fewer process measuring points – multivariable measurement (flow,
density, temperature). Space‐saving installation – no in/outlet run needs.
Flow rates up to 45 000 kg/h (1654 lb/min). Volume flow calculation
according to API table 53.
Excellent operational safety – reliable under extreme ambient conditions. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no in/outlet run needs. Flow rates up to 70 000 kg/h (2570 lb/min). Volume flow calculation according to API table 53.
Transmitter features
Easy operation – reduced to application needs. Fast commissioning – pre‐configured devices. Automatic recovery of data for servicing. Robust, ultra‐compact transmitter housing. Pulse output and Modbus RS485.
Space-saving transmitter – full functionality on the smallest footprint. Fast commissioning – pre-configured devices. Automatic recovery of data for servicing. Robust, compact transmitter housing. Modbus RS485.
Średnica nominalna
DN 8 to 40 (³⁄₈ to 1½")
DN 8 to 50 (³⁄₈ to 2")
Materiały w kontakcie z medium
Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)
Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)
Wielkości mierzone
Mass flow, density, temperature, volume flow, corrected volume flow
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Maksymalny błąd pomiaru
Mass flow (liquid): ±0.2 %
Volume flow (liquid): ±0.3 %
Mass flow (liquid): ±0.20 %
Volume flow (liquid): ±0.30 %
Zakres pomiarowy
0 to 45 000 kg/h (0 to 1650 lb/min)
0 to 70 000 kg/h (0 to 2570 lb/min)
Maks. ciśnienie procesu
PN 40, Class 300, 63K
PN 40, Class 300
Zakres temperatury medium
–40 to +125 °C (–40 to +257 °F)
–50 to +125 °C (–58 to +257 °F)
Temperatura otoczenia
–40 to +60 °C (–40 to +140 °F)
–40 to +60 °C (–40 to +140 °F)
Materiał obudowy czujnika
1.4301 (304), corrosion resistant
1.4301 (304), corrosion resistant
Materiał obudowy przetwornika
Powder‐coated die‐cast aluminium
AlSi10Mg, coated
Stopień ochrony
IP67, type 4X enclosure
IP66/67, type 4X enclosure
Wyświetlacz