Technical data

Thermometer
Measuring PrincipleThermocouple
Characteristic / ApplicationUS style
modular temperature assembly
for heavy duty applications
flanged process connection
with extension
incl. thermowell / protection tube (metal)
Terminal headTMT162 - aluminium - fieldhousing w. or w/o. display
TMT142 - aluminium - fieldhousing w. or w/o. display
Alu - screwed cover w. chain - E+H blue - Grp. A-G
Alu - screwed cover w. chain - grey - Grp. B-G
316SS - screwed cover w. chain - Grp. B-G
Thermowell / protection tubebar stock (drilled)
Insert / probemineral insulated (MI), flexible
Outer diameter protection tube7/8'' (22,23 mm)
17/16'' (26,99 mm)
Max. immersion length on requestup to 2.743 mm (108,00'')
Material protection tube/ thermowell1.4401 (316)
Optional coatingNot defined
Process connectionflange:
ASME 1" 150 RF (B16.5)
ASME 1" 300 RF (B16.5)
ASME 1" 600 RF (B16.5)
ASME 1,5" 150 RF (B16.5)
ASME 1,5" 300 RF (B16.5)
ASME 1,5" 600 RF (B16.5)
ASME 2" 300 RF (B16.5)
ASME 2" 600 RF (B16.5)
Tip shapestraight
tapered
Surface roughness Ra1,6 μm (63,0 μin.)
Operating temperature rangeType T:
-270 °C ...370 °C
(-454 °F ...698 °F)
Type J:
-210 °C ...720 °C
(-346 °F ...1.328 °F)
Type E:
-270 °C ...820 °C
(-454 °F ...1.508 °F)
Type K:
-270 °C ... 1.150 °C
(-454 °F ...2.102 °F)
Type N:
-270 °C ... 1.150 °C
(-454 °F ...2.102 °F)
Max. process pressure (static)at 20 °C: 500 bar (7.252 psi)
Accuracyclass 1 acc. to IEC 60584
class 2 acc. to IEC 60584
Response timedepending on configuration
63% rt = 15 s
Integration head transmitteryes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvalsFM XP
CSA XP
FM/CSA XP
CSA
CertificationSIL (transmitter only)