Technical data

Continuous / Liquids
Measuring PrincipleGuided radar
Characteristic / ApplicationPremium device. Hygiene
Rod probe, ASME BPE + USP Class VI compliant, Integrated data memory, Factory precalibrated, Reliable measuring: in case of moved surface + foam, for changing medias, for filling via spray head.
Supply / Communication2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
4-wire (HART)
AccuracyRod probe:+/- 2 mm (0.08 in)
Ambient temperature-40...+80 °C
(-40...+176 °F)
Process temperature–20...+150 °C
( –4...+302 °F)
Process pressure absolute / max. overpressure limitVacuum...16 bar
(Vacuum...232 psi)
Main wetted partsRod probe:
304, 304L, 316L, PEEK
Process connectionThread:
M24
Process connection hygienicTri-Clamp
DIN11851
DIN11864-1
NEUMO
Varivent N
SMS

Sensor lengthRod probe: 6 m (20 ft)
Max. measurement distanceRod: 6 m (20 ft)
Min DK>1.6
Communication4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus

Certificates / ApprovalsATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC

Safety approvalsOverfill prevention WHG
SIL

Design approvalsEN 10204-3.1

Hygienic approvals3A, EHEDG
CoC ASME-BPE

OptionsSensor remote with 3 m/9 ft or 6 m/18 ft cable
Weld-in adpater