Műszaki adatok

Continuous / Liquids
Mérési elvGuided radar
Characteristic / ApplicationCoaxial probe:
not affected by nozzle dimensions or tank installations

Rod probe:
for measurement in highly viscous media

Rope probe:
large measurement range even with small process connection
Interface measurementClean interfaces liquid / liquid
Simultaneous measurment of interface and overall level

Supply / Communication2-wire (HART / PROFIBUS PA / FOUNDATION Fieldbus )
AccuracyCoaxial probe: +/-3 mm (0.12")
Rod probe: +/-3 mm (0.12")
Rope probe: +/-3 mm (0.12"), >10m:0.03%
Ambient temperature-40 °C ... 80 °C
(-40 °F ... 176 °F)

Process temperatureXT-Version:
-200 °C ... 280 °C
(-328 °F ... 536 °F)
HT-Version:
-200 °C ... 400 °C
(-328 °F ... 752 °F)

Process pressure absolute / max. overpressure limitVacuum ... 400 bar
(Vaccum ... 5802 psi)
Main wetted partsCoaxial probe: 316L, Alloy C22
Rod probe: 316L, Alloy C22
Rope probe: 316
Process connectionFlange:
EN 1092-1 B: DN50, DN80, DN100
ASME: 2", 3", 4"
JIS: DN50, DN80, DN100
Sensor lengthRod: 4 m (178")
Coax: 4 m (178")
Rope: 35 m (1378")

Max. measurement distanceCoaxial probe :
4 m (178") Min. DK > 1.4
Rod probe :
4 m (178") Min. DK > 1.6
Rope probe :
35 m (1378") Min. DK > 1.6

Communication4 ... 20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / ApprovalsATEX
FM
CSA
WHG/ Overfill prevention
SIL
NACE
EN10204-3.1
SuccessorFMP54
Application limitsHorizontal storage tank cyl.:
Use coax probe

Interface measurement:
Use coax system in favor (coax probe, bypass, stilling well)