Technische gegevens

Continuous / Solids
MeetprincipeUltrasonic
Characteristic / ApplicationSeparated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter
Supply / Communication4-wire (HART , Profibus DP)
Accuracy+/- 2mm + 0.17% of measured distance
Ambient temperature-40 °C ... 80 °C
or 150 °C
(-40 °F ... 176 °F
or 302 °F)
Process temperature-40 °C ... 80 °C
or 150 °C
(-40 °F ... 176 °F
or 302 °F)
Process pressure absolute / max. overpressure limit0.7 bar ... 1.5 bar abs
(10 psi ... 22 psi)
Main wetted partsUP (unsaturated polyester)
Silicon / PE foam (80°C / 176°F)
Silicon / stainless steal (150°C / 302°F))

Process connectionG / NPT 1"
Blocking distance0.7 m / 80 °C
(2.3 ft / 176 °F)
0.9 m / 150 °C
(2.9 ft / 302 °F)
Max. measurement distance45 m (148 ft)
CommunicationTransmitter:
4 ... 20 mA HART
Profibus DP

Certificates / ApprovalsATEX, FM, CSA, IEC Ex, INMETRO, NEPSI

OptionsSecond 4...20mA output
ComponentsTransmitter:
FMU90