| Measuring Principle | Coriolis | |
| Product headline | Robust flowmeter with genuine loop-powered technology.
Highest measurement performance for liquids and gases in a wide range of applications. | |
| Sensor features | Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Mass flow: measured error ±0.1 %. Medium temperature up to +205 °C (+401 °F). Nominal diameter: DN 8 to 80 (³⁄₈ to 3"). | |
| Transmitter features | Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area). | |
| Nominal diameter range | DN 8 to 80 (⅜ to 3") | |
| Wetted materials | Measuring tube: 1.4539 (904L); 1.4404; Alloy C22, 2.4602 (UNS N06022) Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) | |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density | |
| Max. measurement error | Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.25 % Density (liquid): ±0.0005 g/cm³ | |
| Measuring range | 0 to 70 000 kg/h (0 to 2570 lb/min) | |
| Max. process pressure | PN 100, Class 600, 63K | |
| Medium temperature range | Standard: –50 to +150 °C (–58 to +302 °F) Option: –50 to +205 °C (–58 to +401 °F) | |
| Ambient temperature range | –40 to +60 °C (–40 to +140 °F) | |
| Sensor housing material | 1.4301/1.4307 (304L), corrosion resistant | |
| Transmitter housing material | AlSi10Mg, coated, 1.4404 (316L) | |
| Degree of protection | IP66/67, type 4X enclosure | |
| Display/Operation | 4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available | |
| Outputs | 4‐20 mA HART (passive) 4‐20 mA (passive) Pulse/frequency/switch output (passive) | |
| Inputs | None | |
| Digital communication | HART, PROFIBUS PA, FOUNDATION Fieldbus | |
| Power supply | DC 18 to 35 V (4‐20 mA HART with/without pulse/frequency/switch) DC 18 to 30 V (20 mA HART, 4‐20 mA) DC 9 to 32 V (PROFIBUS PA) | |
| Hazardous area approvals | ATEX, IECEx, cCSAus, INMETRO, NEPSI, JPN, UK Ex | |
| Product safety | CE, C-TICK | |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 | |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) | |
| Pressure approvals and certificates | PED, CRN, AD 2000 | |
| Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK | |
| Hygienic approvals and certificates | 3-A, EHEDG, cGMP | |
| Measuring Principle | Coriolis | |
| Product headline | Robust flowmeter with genuine loop-powered technology.
Highest measurement performance for liquids and gases in a wide range of applications. | |
| Sensor features | Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Mass flow: measured error ±0.1 %. Medium temperature up to +205 °C (+401 °F). Nominal diameter: DN 8 to 80 (³⁄₈ to 3"). | |
| Transmitter features | Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area). | |
| Nominal diameter range | DN 8 to 80 (⅜ to 3") | |
| Wetted materials | Measuring tube: 1.4539 (904L); 1.4404 ; Alloy C22, 2.4602 (UNS N06022) Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) | |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density | |
| Max. measurement error | Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.25 % Density (liquid): ±0.0005 g/cm³ | |
| Measuring range | 0 to 70 000 kg/h (0 to 2570 lb/min) | |
| Max. process pressure | PN 100, Class 600, 63K | |
| Medium temperature range | Standard: –50 to +150 °C (–58 to +302 °F) Option: –50 to +205 °C (–58 to +401 °F) | |
| Ambient temperature range | –40 to +60 °C (–40 to +140 °F) | |
| Sensor housing material | 1.4301/1.4307 (304L), corrosion resistant | |
| Transmitter housing material | AlSi10Mg, coated, 1.4404 (316L) | |
| Degree of protection | IP66/67, type 4X enclosure | |
| Display/Operation | 4‐line backlit display with touch control
(operation from outside) Configuration via local display and operating tools possible Remote display available | |
| Outputs | 4‐20 mA HART (passive) 4‐20 mA (passive) Pulse/frequency/switch output (passive) | |
| Inputs | None | |
| Digital communication | HART, PROFIBUS PA, FOUNDATION Fieldbus | |
| Power supply | DC 18 to 35 V (4‐20 mA HART with/without
pulse/frequency/switch) DC 18 to 30 V (20 mA HART, 4‐20 mA) DC 9 to 32 V (PROFIBUS PA) | |
| Hazardous area approvals | ATEX, IECEx, cCSAus, INMETRO, NEPSI, JPN, UK Ex | |
| Product safety | CE, C-Tick, EAC marking | |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 | |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) | |
| Pressure approvals and certificates | PED, CRN, AD 2000 | |
| Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK | |
| Hygienic approvals and certificates | 3-A, EHEDG, cGMP | |
| Measuring Principle | Coriolis | |
| Product headline | Robust flowmeter with genuine loop-powered technology.
Highest measurement performance for liquids and gases in a wide range of applications. | |
| Sensor features | Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Mass flow: measured error ±0.1 %. Medium temperature up to +205 °C (+401 °F). Nominal diameter: DN 8 to 80 (³⁄₈ to 3"). | |
| Transmitter features | Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area). | |
| Nominal diameter range | DN 8 to 80 (⅜ to 3") | |
| Wetted materials | Measuring tube: 1.4539 (904L); 1.4404; Alloy C22, 2.4602 (UNS N06022) Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) | |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density | |
| Max. measurement error | Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.25 % Density (liquid): ±0.0005 g/cm³ | |
| Measuring range | 0 to 70 000 kg/h (0 to 2570 lb/min) | |
| Max. process pressure | PN 100, Class 600, 63K | |
| Medium temperature range | Standard: –50 to +150 °C (–58 to +302 °F) Option: –50 to +205 °C (–58 to +401 °F) | |
| Ambient temperature range | –40 to +60 °C (–40 to +140 °F) | |
| Sensor housing material | 1.4301/1.4307 (304L), corrosion resistant | |
| Transmitter housing material | AlSi10Mg, coated, 1.4404 (316L) | |
| Degree of protection | IP66/67, type 4X enclosure | |
| Display/Operation | 4‐line backlit display with touch control
(operation from outside) Configuration via local display and operating tools possible Remote display available | |
| Outputs | 4‐20 mA HART (passive) 4‐20 mA (passive) Pulse/frequency/switch output (passive) | |
| Inputs | None | |
| Digital communication | HART, PROFIBUS PA, FOUNDATION Fieldbus | |
| Power supply | DC 18 to 35 V (4‐20 mA HART with/without
pulse/frequency/switch) DC 18 to 30 V (20 mA HART, 4‐20 mA) DC 9 to 32 V (PROFIBUS PA) | |
| Hazardous area approvals | ATEX, IECEx, cCSAus, INMETRO, NEPSI, JPN, UK Ex | |
| Product safety | CE, C-TICK | |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 | |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) | |
| Pressure approvals and certificates | PED, CRN, AD 2000 | |
| Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK | |
| Hygienic approvals and certificates | 3-A, EHEDG, cGMP | |