| Measuring Principle | Coriolis | |
| Characteristic / Application | An alternative to conventional volumetric flowmeters, this flowmeter has a low "cost of ownership". | |
| Ambient temperature | -20...+65°C (-4...+140°F) | |
| Process temperature | -40...+125°C (-40...+257°F) | |
| Process pressure | PN 40...100 Cl150...600 JIS 10...63K | |
| Wetted parts | 904L/1.4539 | |
| Output | 4...20mA Pulse/Frequency Status | |
| Certificates / Approvals | ATEX FM CSA | |
| Measuring Principle | Coriolis | |
| Product headline | The flowmeter for minimized cost of ownership with a compact or remote transmitter. Highly accurate measurement of liquids and gases for a wide range of standard applications. | |
| Sensor features | Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Compact dual‐tube system. Medium temperature up to +140 °C (+284 °F). | |
| Transmitter features | Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version. | |
| Nominal diameter range | DN 8 to 80 (⅜ to 3") | |
| Wetted materials | Measuring tube: 1.4539 (904L) Connection: 1.4404 (316/316L) | |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density | |
| Max. measurement error | Mass flow (liquid): ±0.20 % (standard) Volume flow (liquid): ±0.20 % Mass flow (gas): ±0.75 % Density (liquid): ±0.0005 g/cm³ | |
| Measuring range | 0 to 180 000 kg/h (0 to 6600 lb/min) | |
| Max. process pressure | PN 100, Class 600, 63K | |
| Medium temperature range | –40 to +140 °C (–40 to +284 °F) | |
| Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) | |
| Sensor housing material | 1.4301 (304), corrosion resistant | |
| Transmitter housing material | Powder‐coated die‐cast aluminium 1.4301 (304), sheet CF3M (316L), cast | |
| Degree of protection | IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure | |
| Display/Operation | 2‐line backlit display with push buttons Configuration via local display and operating tools possible | |
| Outputs | 3 outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive) | |
| Inputs | Status input | |
| Digital communication | HART PROFIBUS PA | |
| Power supply | DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz) | |
| Hazardous area approvals | ATEX, IECEx, FM, CSA, NEPSI | |
| Product safety | CE, C-tick, EAC marking | |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 | |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR | |
| Marine approvals and certificates | Marine approval | |
| Pressure approvals and certificates | PED, CRN | |
| Material certificates | 3.1 material | |
| Hygienic approvals and certificates | 3-A | |
| Measuring Principle | Coriolis | |
| Product headline | The flowmeter for minimized cost of ownership with a compact or remote transmitter. Highly accurate measurement of liquids and gases for a wide range of standard applications. | |
| Sensor features | Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Compact dual‐tube system. Medium temperature up to +140 °C (+284 °F). | |
| Transmitter features | Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version. | |
| Nominal diameter range | DN 8 to 80 (⅜ to 3") | |
| Wetted materials | Measuring tube: 1.4539 (904L) Connection: 1.4404 (316/316L) | |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density | |
| Max. measurement error | Mass flow (liquid): ±0.20 % (standard)
Volume flow (liquid): ±0.20 % Mass flow (gas): ±0.75 % Density (liquid): ±0.0005 g/cm³ | |
| Measuring range | 0 to 180 000 kg/h (0 to 6600 lb/min) | |
| Max. process pressure | PN 100, Class 600, 63K | |
| Medium temperature range | –40 to +140 °C (–40 to +284 °F) | |
| Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) | |
| Sensor housing material | 1.4301 (304), corrosion resistant | |
| Transmitter housing material | Powder‐coated die‐cast aluminium 1.4301 (304), sheet CF3M (316L), cast | |
| Degree of protection | IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure | |
| Display/Operation | 2‐line backlit display with push buttons Configuration via local display and operating tools possible | |
| Outputs | 3 outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive) | |
| Inputs | Status input | |
| Digital communication | HART PROFIBUS PA | |
| Power supply | DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz) | |
| Hazardous area approvals | ATEX, IECEx, FM, CSA, NEPSI | |
| Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine PED, CRN 3-A | |
| Product safety | CE, C-tick, EAC marking | |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 | |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR | |
| Marine approvals and certificates | Marine approval | |
| Pressure approvals and certificates | PED, CRN | |
| Material certificates | 3.1 material | |
| Hygienic approvals and certificates | 3-A | |
| Measuring Principle | Coriolis | |
| Product headline | The flowmeter for minimized cost of ownership with a compact or remote transmitter. Highly accurate measurement of liquids and gases for a wide range of standard applications. | |
| Sensor features | Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Compact dual‐tube system. Medium temperature up to +140 °C (+284 °F). | |
| Transmitter features | Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version. | |
| Nominal diameter range | DN 8 to 80 (⅜ to 3") | |
| Wetted materials | Measuring tube: 1.4539 (904L) Connection: 1.4404 (316/316L) | |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density | |
| Max. measurement error | Mass flow (liquid): ±0.20 % (standard)
Volume flow (liquid): ±0.20 % Mass flow (gas): ±0.75 % Density (liquid): ±0.0005 g/cm³ | |
| Measuring range | 0 to 180 000 kg/h (0 to 6600 lb/min) | |
| Max. process pressure | PN 100, Class 600, 63K | |
| Medium temperature range | –40 to +140 °C (–40 to +284 °F) | |
| Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) | |
| Sensor housing material | 1.4301 (304), corrosion resistant | |
| Transmitter housing material | Powder‐coated die‐cast aluminium 1.4301 (304), sheet CF3M (316L), cast | |
| Degree of protection | IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure | |
| Display/Operation | 2‐line backlit display with push buttons Configuration via local display and operating tools possible | |
| Outputs | 3 outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive) | |
| Inputs | Status input | |
| Digital communication | HART PROFIBUS PA | |
| Power supply | DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz) | |
| Hazardous area approvals | ATEX, IECEx, FM, CSA, NEPSI | |
| Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine PED, CRN 3-A | |
| Product safety | CE, C-tick, EAC marking | |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 | |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR | |
| Marine approvals and certificates | Marine approval | |
| Pressure approvals and certificates | PED, CRN | |
| Material certificates | 3.1 material | |
| Hygienic approvals and certificates | 3-A | |