Nr | Order code | Specification |
F | 71029347 | Kit power s.b. Pmag55 all voltage 85-260VAC 20-55VAC 20-64 VDC
|
F | 71039470 | Kit p.s.b.55 all voltage HE 85-260VAC 20-55VAC 20-64 VDC HE = harsh environment
|
7 | 50094003 | Kit 10 fuses 250 VAC T 2A00 |
B | 71029343 | Kit meas. amplifier Pmag 55 WEA Language: FR,ES,IT,NL,PT,DE,EN
|
B | 71039462 | Kit meas. amplifier 55 WEA HE Language: FR, ES, IT, NL, PT, DE, EN HE = harsh environment
|
B | 71029344 | Kit meas. amplifier Pmag 55 ESS Language: SV,FI,NO,RU,PL,CS,EN
|
B | 71039463 | Kit meas. amplifier 55 EES HE Language: SV, FI, NO, RU, PL, CS, EN HE = harsh environment
|
B | 71029345 | Kit meas. amplifier Pmag 55 SEA Language: JA,ID,EN
|
B | 71039464 | Kit meas. amplifier 55 SEA HE Language: JA, ID, EN HE = harsh environment
|
B | 71029346 | Kit meas. amplifier Pmag 55 CN Language: ZH,EN
|
B | 71039465 | Kit meas. amplifier 55 CN HE Language: ZH, EN HE = harsh environment
|
C | 50098300 | Kit commodul current/freq./2Relay Ex 53/55/83/93/65
|
C | 71039475 | Kit I/O current/frequency/2Relay HE EX 53/55/83 HE = harsh environment
|
C | 50098301 | Kit com 53/55/83/93 curr./freq. out Ex |
C | 71039476 | Kit I/O current/frequency out HE EX 53/55/83 HE = harsh environment
|
C | 71066579 | Kit I/O Profibus PA Ex 50/53/55/80/83/93/65
|
C | 71066580 | Kit I/O 50/53/55/80/83 Profib. PA HE Ex HE = harsh environment
|
C | 50101264 | Kit I/O Foundation Fieldbus C02 Ex 53/55/83/93
|
C | 71095035 | Kit I/O Foundation Fieldbus C14 EX 53/55/83/93/65
|
C | 71039483 | Kit I/O Foundation Fieldbus HE C02 EX 53/55/83 HE = Harsh Environment
|
C | 71095037 | Kit I/O Foundation Fieldbus HE C14 EX 53/55/83 HE = Harsh Environment
|
C | 71021742 | Kit I/O 50/53/55/83/65/8ME Profib. DP Ex |
C | 71039484 | Kit I/O 50/53/55/83 Profibus DP HE EX HE = harsh environment
|
D | 50108002 | Kit I/O Profib. DP+Stat.In 2 Interf. Ex 53/55/83/93
|
D | 71039486 | Kit I/O Profib.DP+Stat.In 2 Interf.HE EX 53/55/83 HE = harsh environment
|
D | 50096833 | Kit Commodul current out 3 Interface Ex 53/55/8X/93/65
|
D | 71039477 | Kit I/O current out 3 Interface HE EX 53/55/8X HE = harsh environment
|
2 | 50096834 | Kit Sub PCB current out 53/55/8X/93/65
|
2 | 71039487 | Kit Sub PCB current out HE 53/55/8X HE = harsh environment
|
3 | 50096835 | Kit Sub PCB frequency out 53/55/80/83/93/65
|
3 | 50096835 | Kit Sub PCB frequency out 53/55/80/83/93/65
|
3 | 71039489 | Kit Sub PCB frequency out HE 53/55/80/83 HE = harsh environment
|
3 | 71039489 | Kit Sub PCB frequency out HE 53/55/80/83 HE = harsh environment
|
4 | 50096837 | Kit Sub PCB Status input 53/55/8X/93/65
|
4 | 71039492 | Kit Sub PCB Status input HE 53/55/8X HE = harsh environment
|
5 | 50096836 | Kit Sub PCB Relay out 53/55/83/84/93/8CN/8DF
|
5 | 50096836 | Kit Sub PCB Relay out 53/55/83/84/93/8CN/8DF
|
5 | 71039491 | Kit Sub PCB Relay out HE 53/55/83/84/8CN/8DF HE = Harsh environment
|
5 | 71039491 | Kit Sub PCB Relay out HE 53/55/83/84/8CN/8DF HE = Harsh environment
|
6 | 50098562 | Kit Sub PCB current in 53/55/83/65
|
6 | 71039488 | Kit Sub PCB current input HE 53/55/83 HE = harsh environment
|
E | 50096754 | Kit display module 53/55/83/84/93/8CN/8DF
|
E | 50096755 | Kit display modul Wall enclosure 53/55/83/84/93/8CN/8DF
|
G | 50094016 | Kit Bus/connec.b.5X/40/8X/65 field hous. |
H | 50099099 | Kit Bus/connec.b.5X/8X SS-housing |
21 | 50094017 | Kit Bus PCB/PCB carr.5X/8X/9X/65 wall |
18 | 50094014 | Kit connec. board In/Output Wall encl |
19 | 50094015 | Kit connec. board PMAG5X wall enclo. |
19 | 71039496 | Kit connec. board 50/53/55 wall encl.HE HE = harsh environment
|
29 | 50108139 | Kit Termin.Block field hous. 5X/8X/40/65 |
30 | 50108140 | Kit Termin.Block Wall encl. 5X/8X/9X/65 |
1 | 50094004 | Kit T-DAT Transmitter Data Chip |
S | 71029348 | Kit S-Dat Pmag 55 programmed Serialnumber is forceful required
|
17 | 50099100 | Kit Cover 5X/8X with window SS-housing |
8 | 50094026 | Kit Cover 5X/40/8X/65 with window |
9 | 50094028 | Kit Cover 5X/40/8X/65 version blind |
10 | 50094038 | Kit Cover Connection terminal 10/5X/40/8X/93/65/400/800
|
| 71309084 | Kit Cover repair for G04 Usage: 10H,50H,53H,55H
|
15 | 50096840 | Kit 10 cable glands M20x1,5 |
15 | 50096840 | Kit 10 cable glands M20x1,5 |
15 | 50094984 | Kit Cable gland Found. Fieldbus |
15 | 50098037 | Kit Cable gland Profibus PA |
15 | 50098041 | Kit 10 ext. M20x1.5/G 1/2" (plug PVC) |
15 | 50098042 | Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC) |
12 | 50096839 | Kit Circuit board cpl field/SS-housing |
13 | 50096841 | Kit Ground terminal / Cover clamp |
14 | 50099102 | Kit Bushing to field/SS-housing |
20 | 50094041 | Kit Seal cover to Wall enclosure |
11 | 50094050 | Kit 10 Seal cover to field housing |
16 | 50099101 | Kit housing gaskets SS-Field housing |
25 | 50098019 | Kit parts housing FS Stnd/HT Usage: 10/50/51/53/55/400/800 Sensor: D/E/H/L/P/S/W
|
23 | 50098020 | Kit parts housing compact Stnd/HT Usage: 10/23/50/51/53/55 Sensor: D/E/H/L/P/S/W
|
22 | 50098021 | Kit housing gaskets H compact |
24 | 50098022 | Kit housing gaskets H FS |
| 71129286 | Kit 8 special screws M6 Promag H DN25 M6x16/5,0 6kt, ISO4017 A2
|
| DK5CA- | Promag, cable remote version 10/50/51/53/55/400/800 1 kit includes 1 coil cable and 1 signal cable
Cable, Remote Version: | 1 | 5m/15ft | 2 | 10m/30ft | 4 | ..... m | 5 | ..... ft | Approval: | A | Non-hazardous area + ATEX II 3G, FM/CSA |
|
| 55XXX- | Promag 55, transmitterApplication: | XXX | Promag 55S, 55H | Version: | XX | Transmitter only | Approval: | A | Non-hazardous area | R | FM NI Cl. I Div. 2 / CSA Cl. I Div. 2 | Housing: | 1 | Compact Alu, IP67 NEMA4X, -40oC/oF Sensor see specification | 2 | Compact stainless, IP67 NEMA4X, -40oC/oF Sensor see specification | 3 | Wall Alu, IP67 NEMA4X, -40oC/oF Sensor see specification | 9 | Special version, TSP-no. to be spec. | A | Compact Alu, IP67 NEMA4X | B | Compact stainless, IP67 NEMA4X | C | Wall Alu, IP67 NEMA4X | P | Compact Alu, IP67 NEMA4X, HE HE= harsh environment | R | Compact stainless, IP67 NEMA4X, HE HE= harsh environment | S | Wall Alu, IP67 NEMA4X, HE HE= harsh environment | Cable, Remote Version: | 0 | Not used | 1 | 5m/15ft coil and signal cable | 2 | 10m/30ft coil and signal cable | 4 | ..... m coil and signal cable | 5 | ..... ft coil and signal cable | 9 | Special version, TSP-no. to be spec. | Cable Entry: | 9 | Special version, TSP-no. to be spec. | A | Gland M20 (EEx d > thread M20) | B | Thread NPT 1/2 | C | Thread G 1/2 | K | Bus plug + gland M20 | L | Bus plug + thread NPT 1/2 | M | Bus plug + thread G 1/2 | Power Supply; Display: | 7 | 85-260VAC, WEA, w/o display, Remote configuration WEA= language DE+EN+FR+IT+ES+PT+NL | 8 | 20-55VAC / 20-64VDC, WEA, w/o display, Remote configuration WEA= language DE+EN+FR+IT+ES+PT+NL | 9 | Special version, TSP-no. to be spec. | A | 85-260VAC, WEA, 4-line + Touch control WEA= language DE+EN+FR+IT+ES+PT+NL | B | 20-55VAC / 20-64VDC, WEA, 4-line + Touch control, WEA= language DE+EN+FR+IT+ES+PT+NL | C | 85-260VAC, SEA, 4-line + Touch control SEA= language JA+ID+EN | D | 20-55VAC / 20-64VDC, SEA, 4-line + Touch control, SEA= language JA+ID+EN | E | 85-260VAC, EES, 4-line + Touch control EES= language SV+FI+NO+RU+PL+CS+EN | F | 20-55VAC / 20-64VDC, EES, 4-line + Touch control, EES= language SV+FI+NO+RU+PL+CS+EN | G | 85-260VAC; CN, 4-line + Touch control, CN= language ZH + EN | H | 20-55VAC / 20-64VDC; CN, 4-line + Touch control, CN= language ZH + EN | Adjustment; Software Feature: | 9 | Special version, TSP-no. to be spec. | A | Factory setup; basic version | C | Factory setup; ECC electrode cleaning circuit | E | Factory setup; advanced diagnostics | G | Factory setup; advanced diagnostics + ECC electrode cleaning circuit | J | Factory setup; Solid Content Flow | L | Factory setup; Solid Content Flow + ECC electrode cleaning circuit | N | Factory setup; Solid Content Flow + advanced diagnostics | R | Factory Setup; Solid Content Flow + ECC+ advanced diagnostics | Output, Input: | 2 | 4-20mA HART + 20mA + freq. + relay M= modules exchangeable | 3 | 4-20mA HART + mA + freq. + 20mA In., modules exchangeable | 4 | 4-20mA HART + freq.+In.20mA+relay M= modules exchangeable | 5 | 4-20mA HART + freq.+In.20mA+stat. M= modules exchangeable | 9 | Special version, TSP-no. to be spec. | A | 4-20mA HART + frequency | B | 4-20mA HART + freq. + 2x relay | C | 4-20mA HART + freq. + 2x relay M= modules exchangeable | D | 4-20mA HART + freq.+relay +stat.In M= modules exchangeable | H | PROFIBUS PA | J | PROFIBUS DP | L | 4-20mA HART + 2x relay + stat.In M= modules exchangeable | M | 4-20mA HART + 2x freq. + stat.In M= modules exchangeable | P | PROFIBUS DP + 20mA + freq.+ stat.In, modules exchangeable | V | PROFIBUS DP + 2x relay + stat.In, modules exchangeable |
|
| DK5WM- | Transmitter Promag, mounting set 10/50/51/53/55/800
Application: | A | Remote, wall / pipe mounting, panel |
|
| DK5SO- | Promag 53/55, software package Chip for release of software functionality. Note: The license is locked to a specific serial number (S-DAT).
Application: | C | ECC electrode cleaning circiut | D | Advanced diagnostics | E | Solid Content Flow |
|
| 55H- | **Promag 55H Electromagnetic flowmeter
Nominal diameters | 02 | DN02 1/12" | 04 | DN04 5/32" | 08 | DN08 5/16" | 15 | DN15 1/2" | 1F | DN150 6" | 1H | DN100 4" | 1Z | DN125 | 22 | DN25 1" ODT, SMS, ANSI, ISO pipes | 26 | DN25 DIN, JIS pipes | 40 | DN40 1 1/2" | 50 | DN50 2" | 65 | DN65 2 1/2" | 80 | DN80 3" | Process Connection: | 0 | Clamp DIN32676, 316L/1.4404 | 1 | Tri-Clamp, 316L/1.4404 | 2 | DIN11851, 316L/1.4404 | 3 | Aseptic DIN11864-1A, 316L/1.4404 | 4 | Aseptic DIN11864-2A, 316L/1.4404 | 5 | SMS1145, 316L/1.4404 | 6 | ISO2853, 316L/1.4404 | 9 | Special version, TSP-no. to be spec. | A | Not used | B | Welding nipple EN ISO1127, 316L/1.4404 (DIN2501) | C | Welding nipple ODT/SMS, 316L/1.4404, O= O-ring | D | PN40, 316L/1.4404, flange EN1092-1 | E | Cl.150, 316L/1.4404, flange ANSI B16.5 | F | 20K, SUS 316L, flange JIS B2220 | G | PN16, PVDF, flange EN1092-1 (DIN2501) | H | Cl.150, PVDF, flange ANSI B16.5 | J | 10K, PVDF, flange JIS B2220 | K | Male thread ISO228, 316L/1.4404 | L | Female thread ISO228, 316L/1.4404 | M | Hose adapter ID=13mm, 316L/1.4404 | N | Hose adapter ID=16mm, 316L/1.4404 | P | Hose adapter ID=19mm, 316L/1.4404 | R | Adhesive fitting tube 1/2", PVC | S | Adhesive fitting 20x2mm tube, PVC | W | Clamp ISO2852, 316L/1.4404 | Seal: | 0 | Not used | 9 | Special version, TSP-no. to be spec. | A | O-ring, EPDM | B | O-ring, Viton | C | O-ring, Kalrez | F | Aseptic shape, EPDM | G | Aseptic shape, Viton | H | Aseptic shape, Silicone | Electrodes: | 0 | 1.4435/316L | 1 | Alloy C-22 | 2 | Tantalum | 5 | Platinum | 9 | Special version, TSP-no. to be spec. | A | 1.4435/316L + grounding rings | B | Alloy C-22 + grounding rings | D | Tantalum + grounding rings | G | 1.4435/316L, bullet nose | Calibration: | 9 | Special version, TSP-no. to be spec. | B | 0.2% | E | 0.2%, 3-point, traceable ISO/IEC17025 | Additional Test, certificate: | 1 | w/o | 2 | Mat. certificate (flange) | 3 | pressure test | 4 | Mat. certificate (flange) + pressure test | 5 | CRN approval | 8 | CRN approval + mat. certicate (flange) + pressure test | 9 | Special version, TSP-no. to be spec. | E | EAC marking | N | EAC marking + mat. certificate (flange) | P | PED Cat. II/III | R | PED Cat. II/III + mat. certificate (flange) | Approval: | A | Non-hazardous area | R | FM NI Cl. I Div. 2 / CSA Cl. I Div. 2 | Housing: | 1 | Compact Alu, IP67 NEMA4X, -40oC/oF Sensor see specification | 2 | Compact stainless, IP67 NEMA4X, -40oC/oF Sensor see specification | 3 | Wall Alu, IP67 NEMA4X, -40oC/oF Sensor see specification | 4 | Compact stainless + Polycarbonate window, IP67 NEMA4X | 9 | Special version, TSP-no. to be spec. | A | Compact Alu, IP67 NEMA4X | B | Compact stainless, IP67 NEMA4X | C | Wall Alu, IP67 NEMA4X | P | Compact Alu, IP67 NEMA4X, HE HE= harsh environment | R | Compact stainless, IP67 NEMA4X, HE HE= harsh environment | S | Wall Alu, IP67 NEMA4X, HE HE= harsh environment | Cable, Remote Version: | 0 | Not used | 1 | 5m/15ft coil and signal cable | 2 | 10m/30ft coil and signal cable | 4 | ..... m coil and signal cable | 5 | ..... ft coil and signal cable | 9 | Special version, TSP-no. to be spec. | Cable Entry: | 9 | Special version, TSP-no. to be spec. | A | Gland M20 (EEx d > thread M20) | B | Thread NPT 1/2 | C | Thread G 1/2 | K | Bus plug + gland M20 | L | Bus plug + thread NPT 1/2 | M | Bus plug + thread G 1/2 | X | Not used, sensor only | Power Supply; Display: | 9 | Special version, TSP-no. to be spec. | X | Sensor only | Adjustment; Software Feature: | 9 | Special version, TSP-no. to be spec. | X | Sensor only | Output, Input: | 9 | Special version, TSP-no. to be spec. | X | Sensor only | >Design: | CA | Process connection short | CB | Process connection short, Ra<0.38um | >>Marking: | Z1 | Tagging (TAG), see additional spec. | Z2 | Bus address, see additional spec. |
|
| DKH- | Promag H, mounting set A mounting set includes 2 process connections incl. screws and the corresponding seals.
Nominal Diameter: | 02 | DN02 1/12" | 04 | DN04 5/32" | 08 | DN08 5/16" | 15 | DN15 1/2" | 1F | DN150 6" | 1H | DN100 4" | 1Z | DN125 | 22 | DN25 1" ODT, SMS, ANSI, ISO pipes | 26 | DN25 DIN, JIS pipes | 40 | DN40 1 1/2" | 50 | DN50 2" | 65 | DN65 2 1/2" | 80 | DN80 3" | Process Connection: | 99 | Special version, TSP-no. to be spec. | AA | Welding nipple EN ISO1127, 316L/1.4404 | AB | Welding nipple ODT/SMS, 316L/1.4404, O= O-ring | FA | PN40, 316L/1.4404, flange EN1092-1 | FB | Cl.150, 316L/1.4404, flange ANSI B16.5 | FC | 20K, SUS 316L, flange JIS B2220 | FD | PN16, PVDF, flange EN1092-1 (DIN2501) | FE | Cl.150, PVDF, flange ANSI B16.5 | FF | 10K, PVDF, flange JIS B2220 | GA | Male thread ISO228, 316L/1.4404 | GB | Female thread ISO228, 316L/1.4404 | GE | Hose adapter ID=13mm, 316L/1.4404 | GF | Hose adapter ID=16mm, 316L/1.4404 | GH | Hose adapter ID=19mm, 316L/1.4404 | GJ | Adhesive fitting tube 1/2", PVC | GK | Adhesive fitting 20x2mm tube, PVC | HA | Welding nipple EN10357, 1.4404/316L (DIN11850) | HB | Welding nipple ODT/SMS, 316L/1.4404 | HC | Clamp ISO2852, 316L/1.4404 | HD | Clamp DIN32676, 316L/1.4404 | HE | Tri-Clamp, 316L/1.4404 | HG | DIN11851, 316L/1.4404 | HH | Aseptic DIN11864-1A, 316L/1.4404 | HJ | Aseptic DIN11864-2A, 316L/1.4404 | HK | SMS1145, 316L/1.4404 | HL | ISO2853, 316L/1.4404 | HN | Welding nipple ASME BPE, 1.4404/316L | HP | Welding nipple ISO2037, 1.4404/316L | Seal: | 9 | Special version, TSP-no. to be spec. | A | O-ring, EPDM | B | O-ring, Viton | C | O-ring, Kalrez | F | Aseptic shape, EPDM | G | Aseptic shape, Viton | H | Aseptic shape, Silicone | Additional Test, Certificate: | 1 | w/o | 2 | Mat. certificate (flange) | 9 | Special version, TSP-no. to be spec. | >Design: | CA | Process connection short | CB | Process connection short, Ra<0.38um | CC | ***Process connection old installatiion |
|
| DK5G- | Promag H/Dosimag, seal setNominal Diameter: | 02 | DN02 1/12" | 04 | DN04 5/32" | 08 | DN08 5/16" | 15 | DN15 1/2" | 1F | DN150 6" | 1H | DN100 4" | 1Z | DN125 | 22 | DN25 1" | 26 | DN25 DIN | 40 | DN40 1 1/2" | 50 | DN50 2" | 65 | DN65 | 80 | DN80 3" | For Product: | B | Promag 10H**, 23H**, 50H**, 53H**, 55H** | Seal: | 9 | Special version, TSP-no. to be spec. | A | Aseptic shape | B | O-Ring for 1.4404/316L process connection | C | O-Ring for PVC + PVDF process connection | D | Aseptic shape for EH V3.0 process connection | Material: | 99 | Special version, TSP-no. to be spec. | AB | 2x EPDM | BB | 2x FKM (Viton) | DB | 2x VMQ (Silicone) | EB | 2x Kalrez | >Design: | CA | Short |
|
| DK5HB- | Promag H, distance disc The set includes 2 distance discs incl. screws and 2 seals. For dimensions refer to the technical documentation.
Nominal diameter: | 1H | DN100 4" | 80 | DN80 3" | Process Connection: | 99 | Special version, TSP-no. to be spec. | HS | Distance disc | Seal: | 9 | Special version, TSP-no. to be spec. | F | Aseptic shape, EPDM | G | Aseptic shape, Silicone |
|
| DK5HM- | Promag H, wall mounting setNominal Diameter: | 15 | DN15 1/2" | 22 | DN25 1" | 26 | DN25 DIN | H2 | DN02 1/12" | H4 | DN04 5/32" | H8 | DN08 5/16" |
|
| DK5HW- | Promag H, weld in toolNominal Diameter: | 15 | DN02 - DN15 1/12" - 1/2" | 1F | DN150 6" | 1H | DN100 4" | 1Z | DN125 | 22 | DN25 1" | 26 | DN25 DIN | 40 | DN40 1-1/2" | 50 | DN50 2" | 65 | DN65 2-1/2" | 80 | DN80 3" | Material: | A | 1.4301 |
|
| DK5HA- | Promag H, adapter set Replacement of sensor Promag A or Promag H DN 25. The set includes 2 adapters and 2 seals. For dimensions refer to the technical documentation.
Nominal Diameter: | 15 | DN 15 1/2" | 22 | DN 25 1" | 26 | DN 25 DIN | H2 | DN 02 1/12" | H4 | DN 04 5/32" | H8 | DN 08 5/16" | Process Connection: | 99 | Special version, TSP-no. to be spec. | FA | DN15 PN40, 316L/1.4404, Promag A Flange EN1092-1 (DIN 2501) | FC | DN15 20K, 316L/1.4404, flange JIS B2220 | HC | Clamp ISO2852, 316L/1.4404 | HH | DIN11851, 316L/1.4404 | HK | SMS1145, 316L/1.4404 | HL | Welding nipple EN10357, 1.4404/316L (DIN11850) | HM | Welding nipple ODT/SMS, 316L/1.4404 | Seal: | 9 | Special version, TSP-no. to be spec. | A | O-ring, EPDM | B | O-ring, Viton | C | O-ring, Kalrez | F | Aseptic shape, EPDM | G | Aseptic shape, Viton | H | Aseptic shape, Silicone | Additional Test: | 1 | w/o | 9 | Special version, TSP-no. to be spec. |
|
| DK5HR- | Promag H, grounding ring The grounding ring set includes 2 grounding rings
Nominal Diameter: | 15 | DN15 1/2" | 22 | DN25 1" | 26 | DN25 DIN | H8 | DN2-DN8 1/12" - 5/16" | Material: | 1 | 1.4435/316L, (Electrodes 316L/1.4435) | 2 | Alloy C-22, (Electrodes Alloy C-22) | 5 | Tantalum (Electrodes Tantalum) | Seal: | 0 | Not used | 9 | Special version, TSP-no. to be spec. |
|
| FXA193- | Serviceinterface FXA193 The service interface connects the service port of Proline and ToF devices with the serial interface RS 232C (9 pin.) of a personal computer.
Contents of delivery: - Serviceinterface with RS 232C connection cable (9 pin.) - FXA "USB" cable, the additional power supply for FXA193 from USB-port of the PC.
Approval: | 9 | Special version, TSP-no. to be spec. | A | For use in non-hazardous area | B | ATEX II (1) GD | C | CSA/FM Class I Div. 1 | D | ATEX, CSA, FM | Connection Cable: | 9 | Special version, TSP-no. to be spec. | A | Proline device | B | ToF device | E | Proline and ToF device | F | Ex two-wire device | G | Proline device and Ex two-wire device | H | Proline, ToF and Ex two-wire device | X | Without connection cable |
|