Nr | 订货号 | 规格 |
| | Please return the unit to PC for repair |
1 | 71076316 | 电源适配器12VDC/2500mA LEMO接口 |
2 | 71094796 | 接线端子 |
| 50091703 | 常温型声速传感器 Sound velocity measuring sensors for Prosonic Flow 93; sensor pair for measurement of sound velocity in the fluid. |
| 50091704 | 高温型声速传感器 Sound velocity measuring sensors for Prosonic Flow 93; sensor pair for measurement of sound velocity in the fluid. |
| 71112217 | 传感器 DDU 20 Wall thickness measuring sensor for Prosonic Flow 93T; sensor for measuring pipe wall thickness. |
| | Overview auxiliary equipment see spare part picture |
| 93TA1- | 便携式超声波流量计 93T Battery operated Ultrasonic Flowmeter set incl. datalog function with time stamp, 1 GB USB Stick carry case, charger, battery pack acoustic couple medium 8 hours continious operation. P Sensor set DN15-DN65 1/2-2 1/2"/6MHz: | 9 | Special version, TSP-no. to be spec. | A | not selected | B | -40...100oC/-40...212oF + installation set | C | -40...150oC/-40...302oF + installation set | P Sensor set DN50-DN300 2"-12"/2MHz: | 9 | Special version, TSP-no. to be spec. | A | not selected | B | -40...80oC/-40...176oF + installation set | C | 0...170oC/32...338oF + installation set | P Sensor Set DN100-DN4000 4"-160"/1MHz: | 9 | Special version, TSP-no. to be spec. | A | not selected | B | -40...80oC/-40...176oF + installation set | Sensor Cable: | 9 | Special version, TSP-no. to be spec. | E | 5m/15ft, PTFE, -40...170 oC/-40...338oF | F | 10m/30ft, PTFE, -40...170 oC/-40...338oF | Approval: | A | Non-hazardous area | E | Non-hazardous area + EAC marking | Operation language: | A | WEA = DE+EN+FR+IT+ES+PT+NL | C | SEA = JA+ID+EN | E | EES = SV+FI+NO+RU+PL+CS+EN | G | CN = ZH+EN | >>Sound velocity sensor set: | D1 | DN50-DN3000 2"-180" | >>Wall thickness sensor: | E2 | >DN15 1/2" | >>Additional Test, certificate: | F1 | Verification DN50 2", sensor DN15-DN65 1/2"-2 1/2" | F2 | Verification DN100 4", sensor DN50-DN300 2"-12" | F3 | Verification DN100 4", sensor DN100- DN4000 4"-160" | >>Accessory: | P1 | Cable 93T - FXA193 | P2 | Car charging adapter cable | P3 | Rechargable battery pack 93T, 4000 mAh | P4 | Installation set <4000 160" <80°C | P5 | Cable 93T - FXA291 |
|
| DK9PT- | 超声波93T,流量计传感器 For use with Prosonic Flow 93T portable transmitter P sensor: | 1 | DN15-DN65, -40...100oC, 6.0MHz 1/2…2 1/2", -40…212oF | 2 | DN15-DN65, -40...150oC, 6.0MHz 1/2…2 1/2", -40…302oF | 9 | special version, TSP-no. to be spec. | A | DN100-DN4000, -40...80oC, 1.0MHz 4…169", -40…176oF | B | DN50-DN300, -40...80oC, 2.0MHz 2…12", 40…176oF | F | DN50-DN300, 0...170oC, 2.0MHz 2…12", 40…176oF | Approval: | A | non-hazardous area |
|
| DK9SS- | 超声波91/93/93T,传感器电缆Transmitter: | C | Prosonic Flow 93T | Sensor Type: | E | 93T, P sensor | Sensor cable: | E | 5m/15ft, PTFE, -40...170oC/-40...338oF | F | 10m/30ft, PTFE, -40...170oC/-40...338oF |
|
| DK9SH- | W/P型 传感器座组件 DK9SHSensor holder: | 2 | Clamp On, portable DN15-DN65 1/2"-2 1/2" | 9 | Special version, TSP-no. to be spec. | B | Clamp On, detachable retaining nut W/P sensor DN50-DN4000 2"-160" |
|
| DK9ZT- | 便携式超声波93T附件(含电池组,安装组件等)Accessorie: | 1 | Cable 93T - FXA193 | 2 | Car charging adapter cable | 3 | Rechargeable battery pack 93T, 4000 mAh | 4 | Installation set | 5 | Installation set | 6 | Sensor connector, adapter set W/P sensor | 7 | USB Stick, 1GB | 8 | Cable 93T - FXA291 | A | Cable adapter, 93T to 93P DN15-65 Sensor | B | Installation set | C | Carrying bag |
|
| FXA193- | 通讯接口 FXA193 The service interface connects the service port of Proline and ToF devices with the serial interface RS 232C (9 pin.) of a personal computer. Contents of delivery: - Serviceinterface with RS 232C connection cable (9 pin.) - FXA "USB" cable, the additional power supply for FXA193 from USB-port of the PC. - Service Softw.ToF Tool-Fieldtool Package Approval: | 9 | Special version, TSP-no. to be spec. | A | For use in non-hazardous area | B | ATEX II (1) GD | C | CSA/FM Class I Div. 1 | D | ATEX, CSA, FM | Connection Cable: | 9 | Special version, TSP-no. to be spec. | A | Proline device | B | ToF device | E | Proline and ToF device | F | Ex two-wire device | G | Proline device and Ex two-wire device | H | Proline, ToF and Ex two-wire device | X | Without connection cable |
|