Description | Version | Language | |
Technical Information (TI) | |||
1. | Technical Information MyPro CPM 431 Two-wire transmitter for pH and redox with HART ® communication for use in the Ex and non-Ex areas | ||
Manual de instrucciones (BA) | |||
2. | Manual de Instrucciones Mypro CPM 431 Transmisor a dos hilos para la medida de pH y Redox | ||
3. | Operating Instructions MyPro CPM 431 Profibus Two-wire transmitter for pH with HART communication. | ||
Special Documentation (SD) | |||
4. | MyPro CPM431 / CLM431 spare parts and disassembling Special documentation MyPro CPM431 / CLM431 spare parts and disassembling | ||
5. | Instructions for service kits MyPro MEK Special documentation Instructions for service kits MyPro MEK / CLM431 / CLD431 / CPM431 | ||
Manufacturer Information (MI) | |||
6. | Simatic PDM PROFIBUS Package V1.12.00 Manufacturer Information includes PDM - Device List, Release Notes – PROFIBUS Manufacturer Information for users regarding software updates (following the NAMUR recommendation 53) New software version: 1.12.00 | ||
7. | PRM HART Package V1.08.00 Manufacturer Information includes PRM - Device List, Release Notes – HART Manufacturer Information for users regarding software updates (following the NAMUR recommendation 53) New software version: 1.08.00 | ||
8. | PRM FOUNDATION fieldbus Package V1.05.00 Manufacturer Information includes PRM - Device List, Release Notes – FOUNDATION fieldbus Manufacturer Information for users regarding software updates (following the NAMUR recommendation 53) New software version: 1.05.00 | ||
9. | AMS HART Package V1.12.00 Manufacturer Information includes AMS - Device List, Release Notes – HART Manufacturer Information for users regarding software updates (following the NAMUR recommendation 53) New software version: 1.12.00 | ||
10. | Simatic PDM HART Package 1.14.00 Manufacturer Information includes PDM - Device List, Release Notes – HART Manufacturer Information for users regarding software updates (following the NAMUR recommendation 53) New software version: 1.14.00 | ||
11. | AMS FOUNDATION fieldbus Package V1.06.00 Manufacturer Information includes AMS - Device List, Release Notes – FOUNDATION fieldbus Manufacturer Information for users regarding software updates (following the NAMUR recommendation 53) New software version: 1.06.00 | ||
Competence Brochure (CP) | |||
12. | pH 測定セレクションガイド 産業プロセスにおける pH 測定 | 08/15 | Japanese |
13. | CP00010C pH measurement in industrial processes for US market Selection and engineering guide for your industry and application | 04/15 | English |
14. | Measurement and control aspect of pH using inductively coupled with bidirectional Memosens technology in flue gas desulfurization process White Paper CP971C pH measurement and control in a power utility is an integral part of process. The scrubber efficiency is highlydependent on the pH. Numerous opportunities were revealed for saving time, as well as the cost and materials in power plants. In afossil fuel power plant, the chemical energy stored in coal, oil, natural gas, shale oil, oxygen and air is converted into thermal, mechanical and finally into electrical energy. In other words, water is heated to steam, which spins a steam turbine. The steam turbine drives an electrical generator. | 04/11 | English |
15. | CP01202C pH Sensors:Calibrate, clean, perform a calibration check or...? This white paper will address # Knowing when to do a pH sensor calibration versus a calibration check # How to properly clean a pH sensor # How to perform a pH sensor calibration # A decision tree for step by step guidance | 02/12 | English |
General Station Description (GSD) | |||
16. | GSD Single, GSD_EH_PA_AN_Mypro_0x150D_V02_00_PALIB, 22.04.2014 (Analysis,
Mypro, 0x150D) PROFIBUS PA, PROFIBUS System Version: Any | 2.00.00 | Language neutral |
Electronic Data Description (EDD) | |||
17. | EDD Single, PDM_PA_AN_Mypro_0x150D_0x02_0x01, 07.01.2019 (Analysis, Mypro, 0x150D) PROFIBUS PA, PDM Version: 6.0 SP5 | 1.00.00 | Language neutral |
Device Type Manager (DTM) | |||
18. | DTM Single, MyproPH_CPM431_PA_V2_0, 12.05.2023 (Analysis, Mypro, 0x150D) PROFIBUS PA, DeviceCare Version: 1.07.06 Field Xpert - SMT70 Version: 1.07.00 FieldCare Version: 2.17.00 | 1.5.153.348 | Language neutral |
19. | DTM Single, MyproPH_CPM431_V2_02, 12.05.2023 (Analysis, Mypro, 0x008C) HART, DeviceCare Version: 1.07.06 Field Xpert - SMT70 Version: 1.07.00 FieldCare Version: 2.17.00 | 1.4.188.39 | Language neutral |