Level radar used to measure pneumatic filling through tough build up
with air purge.
 
Micropilot M FMR250 aimed to the angle of repose of the sodium carbonate
allowed the radar signal through the open area in the center of the
tank. Therefore the free space signal was not locking on the product
bridge along the wall of the tank
 