Cyanide oxidation with NaOCl in galvanic industry
AHC Benelux optimises thanks to pH+ORP sensor combined
 
By using the Memosens CPS16D combined pH+ORP sensor in our 2
cyanide oxidation tanks, we control this process accurately. With the
Liquiline CM444 transmitter also the rH value is calculated and in this
way
an optimised process control is realised. The measurements are in use
since May 2013 and since then discharge values of 0,0 mg/l heavy
metals or cyanides to the surface water are obtained.”
 